- Capacity: 1000W Medical-Grade Isolation Transformer with full IEC/EN 60601-1 listing
- Voltage: Selectable 115/230V Step-Up, Step-Down, or Pass-Through operation
- Protection: 240J surge protection, EMI/RFI filtering, leakage current under 80 µA
Protect sensitive electronic equipment and ensure patient safety in medical environments with the Eaton Tripp Lite IS1000HG 1000W Medical-Grade Isolation Transformer. This robust 120V isolation transformer delivers 100% isolation from the input AC line, effectively eliminating electrical noise and interference that can disrupt critical medical devices. With full UL 60601-1 medical-grade listing and specialized hospital-grade NEMA 5-15P input and 4 NEMA 5-15R-HG output receptacles, it’s specifically designed for healthcare settings, providing an inexpensive alternative to costly dedicated circuits and site electrical upgrades.
Reduce cumulative leakage current of connected equipment to less than 100 microamps, crucial for patient care areas, while the integrated Faraday shield and floating AC output prevent noise coupling from noisy hospital ground circuits. This unit also removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops, and significantly reduces 6000V IEEE587 Category A & B surges down to only 0.5V common mode. Housed in a durable all-metal chassis, with a 3.05 m (10 ft) power cord, circuit breaker overload protection, and TAA compliance, the IS1000HG ensures reliable and unwavering power for your most demanding medical applications.
View Data SheetThe Eaton Tripp Lite IS1000HG medical-grade isolation transformer provides complete line isolation and continuous noise filtering, essential for protecting sensitive electronic equipment in patient care areas. Its full UL 60601-1 medical-grade listing and hospital-grade plug and outlet receptacles ensure safety and reliability, while reducing cumulative leakage current to less than 100 microamps and offering a cost-effective alternative to expensive dedicated circuits or electrical upgrades.
| Product Type: | Computing Device Accessory |
|---|---|
| VA / Watt Capacity: | 1000 VA / 1000 W |
| Output Receptacles: | (4) NEMA 5-15R-HG Hospital-Grade Outlets |
| Input Plug: | NEMA 5-15P-HG Hospital Grade |
| Nominal Voltage / Frequency: | 120V AC / 60 Hz |
| Output Amp Capacity: | 8.8A |
| Efficiency: | 96% |
| Total Harmonic Distortion: | Less than 1% |
| Noise Suppression Rating: | 35–65 dB |
| Leakage Current: | Less than 100 microamps |
| Let-through Voltage (Combination Wave): | L-N: 250V | L-G: 250V | N-G: 0.5V |
| Let-through Voltage (Ring Wave): | L-N: 20V | L-G: 20V | N-G: 0.5V |
| Over Current Protection: | 1 x Thermal, 2-pole, 10A |
| Input Cord Length: | 3.05 m (10 ft) |
| Form Factor: | Tower |
| Cooling Method: | Convection |
| Dimensions: | 185 x 184 x 267 mm (7.25 x 7.25 x 10.50 in) |
| Weight: | 17.10 kg (37.70 lbs) |
| Certifications: | UL 60601-1 |
| Compliance: | RoHS, Trade Agreements Act (TAA) |
| Warranty: | 2-Year Limited Warranty |