- Capacity: 7.7kW output with dual IEC309 32A Blue inputs for redundant power
- Outlets: 16 x C13 and 2 x C19 switched outlets across 2 breakered load banks
- Management: LX Platform network interface with SNMP, SSH, and remote outlet control
Achieve unparalleled power reliability and insight for your critical network equipment with the Eaton Tripp Lite PDUMH32HVAT 7.7kW Local Metered ATS PDU. This advanced automatic transfer switch PDU provides continuous power to even non-redundant hardware, ensuring your operations remain online without interruption. Keep tabs on your equipment's power consumption with the multifunction digital display, showing output current, voltage, and kW loading information, allowing you to proactively prevent overloads and costly downtime.
Designed for seamless integration into data centers and server rooms, this 2U rack-mount PDU features dual IEC309 32A blue inputs for connection to separate primary and secondary power sources, with dynamic solid-state (TRIAC) automatic transfer switching occurring within a rapid 1-5 milliseconds. The PDUMH32HVAT provides comprehensive power distribution through 16 C13 and 2 C19 outlets across two circuit breaker-protected load banks, all while being TAA compliant for government purchases.
View Data SheetEnsure uninterrupted power for your vital IT infrastructure with the Eaton Tripp Lite PDUMH32HVAT, an intelligent 7.7kW ATS PDU designed to provide redundant power to even non-redundant equipment through its dual 3m (10 ft) input cords and automatic transfer switching that occurs in just 1–5 milliseconds. Its local metered capabilities, displayed clearly on a multifunction digital interface, allow for real-time monitoring of output current, voltage, and kW loading to proactively prevent overloads and costly downtime in your data center or server room.
| Product Type: | Computing Device Accessory |
|---|---|
| PDU Type: | Local Metered; Auto-Transfer Switch |
| Input Phase: | Single-Phase |
| Input Voltage: | 200-240V |
| Input Plug Type: | (2) IEC-60309 32A Blue (2P+E) |
| Input Cord Length: | 3.05 m (10 ft) per cord |
| Output Capacity: | 7.7kW (240V) / 7.4kW (230V) / 7.0kW (220V); 32A maximum |
| Output Receptacles: | (16) C13, (2) C19 in 2 load banks |
| Output Voltage: | 200-240V |
| Frequency Compatibility: | 50 / 60 Hz |
| Overload Protection: | (2) 20A circuit breakers; 16A max per bank; 10A max per C13; 16A max per C19 |
| Transfer Time: | 1-5 ms |
| Mounting: | 2U Rack-Mount, Horizontal; EIA-Standard 19 in. Racks |
| Rack Height: | 2U |
| Min. Required Rack Depth: | 40.64 cm (16 in) |
| Dimensions: | 88.9 x 444 x 317 mm (3.5 x 17.5 x 12.5 in) |
| Weight: | 6.21 kg (13.7 lbs) |
| Operating Temperature: | 0° to 40°C (32° to 104°F) |
| Storage Temperature: | -30° to 50°C (-22° to 122°F) |
| Relative Humidity: | 5% to 95% non-condensing |
| Operating Elevation: | 0-3000 m (0-10,000 ft) |