- Capacity: 5.8kW Single-Phase ATS PDU with dual L6-30P inputs
- Transfer: Solid-state TRIAC switching within 1-5 ms for uninterrupted operation
- Monitoring: WEBCARDLX with SNMP, SSH, HTML5 web interface and +/-1% accuracy
Ensure uninterrupted power for your mission-critical network equipment with the Eaton Tripp Lite PDUMH30HVATNET 5.8kW Switched PDU, featuring an advanced automatic transfer switch (ATS). This robust 2U rack-mount solution provides redundant power from two separate 200-240V L6-30P inputs, automatically switching to the secondary source in 2-6 milliseconds if the primary input fails or becomes unstable. Monitor and control your power environment with a 2-digit display reporting output consumption in amps, and gain ultimate flexibility with 19 individually switched outlets (16 C13, 2 C19, and 1 L6-30R), preventing accidental disconnections with included plug-lock retention sleeves.
Upgrade your data center's power resilience and remote management capabilities thanks to the pre-installed WEBCARDLX with PowerAlert Device Manager firmware (PADM20). This network card enables real-time monitoring and control of individual outlets, along with user-specified alarm thresholds for all reported site power conditions. Ideal for fault-tolerant and fully redundant UPS protection schemes, this TAA compliant PDU offers seamless integration with existing infrastructure and supports advanced ATS configurations, making it the perfect choice for demanding IT environments.
View Data SheetEnsure uninterrupted power for your critical network equipment with the Eaton Tripp Lite PDUMH30HVATNET, featuring a 5.8kW Automatic Transfer Switch (ATS) that seamlessly shifts power sources in just 2-6 milliseconds. This advanced 2U rack-mount PDU offers superior reliability with redundant power options, 19 individually switched outlets for precise control, and a pre-installed WEBCARDLX for enhanced remote management, making it the ideal solution for maintaining uptime in demanding IT environments.
| Product Type: | Computing Device Accessory |
|---|---|
| PDU Type: | Auto-Transfer Switch (ATS); Switched |
| Input Voltage: | 200-240V Single-Phase |
| Input Current: | 24A Maximum (Agency De-Rated to 24A Continuous) |
| Input Connections: | (2) NEMA L6-30P, 10 ft. (3.05 m) Input Cords |
| Output Capacity: | 5.8kW @ 240V / 5kW @ 208V / 4.8kW @ 200V |
| Output Receptacles: | (16) C13, (2) C19, (1) L6-30R – 19 Total Switched Outlets |
| Frequency: | 50/60 Hz |
| Overload Protection: | Two 20A Output Circuit Breakers (Breaker 1: Outlets 1–9; Breaker 2: Outlets 10–18) |
| Transfer Time: | 2–6 Milliseconds |
| Measurement Accuracy: | ±1% for Current, Voltage, and Power |
| Network Interface: | Pre-installed WEBCARDLX (PADM20); RJ45, Micro-USB, USB-A |
| Network Speed: | 10/100 Mbps (Fast Ethernet) |
| Remote Management: | HTML5 Web Interface, Telnet, SSH, SNMP |
| Mounting: | 2U Horizontal Rack-Mount |
| Dimensions: | 88.9 x 444.5 x 317.5 mm (3.5 x 17.5 x 12.5 in) |
| Weight: | 6.21 kg (13.70 lbs) |
| Min. Required Rack Depth: | 40.64 cm (16 in) |
| Operating Temperature: | 0° to 40°C (32° to 104°F) |
| Storage Temperature: | -30° to 50°C (-22° to 122°F) |
| Relative Humidity: | 5% to 95% Non-Condensing |
| Operating Elevation: | 0–3000 m (0–10,000 ft) |